Skip to content

67 ยท Risk register, the NSCS audit baseline and national CII guidance, all linked

Status: ๐ŸŸก Partly built. Risk register, packs, links, CII self-check and the edge device ports are built and tested; the device ports with a real Tailscale serve are verified only on your laptop. What the lights mean

Risks, controls, audits and incidents describe the same things from different sides. SecuRAX keeps them as one picture:

  NSCS audit markers โ”€โ”                         โ”Œโ”€ navigator (grid, radar, heat map, vital few)
  CII guidance โ”€โ”€โ”€โ”€โ”€โ”€โ”€โ”ผโ”€โ–บ BFSI control library โ—„โ”€โ”ผโ”€ SecuRAX evidence (what it proves)
  RBI/SEBI/IRDAI/... โ”€โ”˜        โ–ฒ                 โ””โ”€ cockpit (master caution)
                               โ”‚ links
  V/T/R register + treatment plans โ”€โ–บ open risks โ”€โ–บ heat map, ranking, overdue lamp โ”€โ–บ postmortems

1. The risk register (./securax risks)

./securax risks import          # finds your registers in Downloads / Documents / Desktop (Windows ones too) and asks once
./securax risks list --open
./securax risks overdue                                    # exit 1 when a treatment is late (a routine can nag)

No path to type: it lists the workbooks that read as a register (the control-library workbook and unrelated sheets are skipped) and asks Import them? [Y/n]. To import one file only, give its path: ./securax risks import FILE.xlsx.

What it reads How
V/T/R registers: risk-wise and asset-wise registers, and the observations tracker by column name, two-row headers included, so a re-ordered or extended workbook still imports
Risk assessment + treatment plan (probability ร— impact, inherent / reduced / residual, treatment type, owner, planned and actual end) the assessment rows are joined to their treatment-plan rows by the treatment reference
Scores the workbooks' own scale: inherent = likelihood (1โ€“5) ร— impact (1โ€“5); 20โ€“25 critical, 12โ€“19 high, 6โ€“11 medium, 1โ€“5 low
  • Private by design. The register is written to vault/risks/register.json, which is never committed. Registers name people, systems and findings; they stay on your machine and in your backups.
  • Linked to controls. Each risk is linked to the library controls that would treat it, from what it is about: access, patching, vendors, backups, malware, physical, encryption, logging, and so on.
  • Re-import is safe. Importing the same file again replaces that file's rows only.
Where What changes
Navigator heat map if you have not scored controls yet, it plots your open risks by likelihood ร— impact
The vital few a control that would treat a high open risk ranks higher (your risk score lifts it)
Navigator master caution a lamp for risk treatments overdue
Cockpit master caution the same lamp, lit only when something is overdue (dark-cockpit rule)
Postmortems after an incident, ./securax postmortem new records the mechanism; the related risk's treatment is where it is tracked

3. NSCS Cyber Security Audit Baseline (NSCS-46-16, Oct 2020)

A pack, governance/controls/packs/nscs-audit-baseline-2020.json, links each of the 68 audit markers to the library controls they test:

  • csm.1โ€“19: management
  • pro.1โ€“21: protection
  • det.1โ€“9: detection
  • res.1โ€“11: response
  • rec.1โ€“3: recovery
  • imp.1โ€“5: lessons learnt

The navigator's regulator table gains a row for it, and every linked control's hover shows its markers. Marker pro.19 (change control) had no matching control, so it became a new one, AS-101.

The baseline has three risk profiles, all recorded in the pack:

Profile Which markers are mandatory
High risk all markers
Medium risk all except pro.12, pro.13, pro.20, det.3, res.1, res.8, which are recommended
Low risk 18 markers are recommended

The publication is licensed CC BY-NC-SA 4.0 (non-commercial), so the pack carries marker IDs and links only, never its text.

4. National CII guidance: evaluating and identifying Critical Information Infrastructure

The pack governance/controls/packs/cii-guidance.json links library controls to two national CII guidance documents.

The Framework for Evaluating Cyber Security in CII (v1) has five phases:

Phase What it covers Linked controls include
I ยท Identify infrastructure structure, systems, ICS/SCADA, networks, services, criticalities, interdependencies, owners asset inventory, data flows, BIA, concentration risk
II ยท Assess V/T/R, network architecture, standards, policies, HR, compliance risk assessment, segmentation, policy library, HR controls, compliance register
III ยท Implement controls โ€” โ€”
IV ยท Verify verifying the controls are implemented continuous control monitoring, VAPT
V ยท Ensure compliance to audit audit IS audit, special audits

The Guidelines for Identification of CII (v1.0, Aug 2019) supply four impact tests: national-scale impact on customers and business, the timeframe to serious impact, geographic spread, and cascading dependency. ./securax risks cii asks them and records the answer:

Result Meaning
Likely CII treat the systems as High-risk infrastructure: every NSCS marker is mandatory. Engage the national CII agency through your sector regulator.
Possibly CII document the assessment and re-check yearly; use the Medium profile
Unlikely CII use the profile your risk assessment sets

It is a self-check: designation is the Government's (section 70, IT Act), on the national CII agency's advice. The issuing agency reserves all rights to its documents, so the pack holds phase and paragraph references only.

5. Professional names and phones together

The https://hub.securax.localhost names come from the HTTPS edge (./securax tls on). Phones over Tailscale used to need it off, because tailscale serve forwards to a port and the edge hid every port behind its single named one.

The edge now also listens on two loopback-only device ports: 9443 for the app (with /v1, /healthz, /version and /sync on the same origin) and 9444 for Chat. ./securax go and ./securax phones --apply point Tailscale at them when the edge is on. So:

Device App Chat
This laptop (edge on) https://hub.securax.localhost https://chat.securax.localhost
Phones https://<laptop>.<tailnet>.ts.net https://<laptop>.<tailnet>.ts.net:10000

To switch: ./securax tls on && ./securax go. Each address keeps its own app data, so open the laptop sync link from ./securax sync-link once at the new address.

When another program already uses port 80 or 443 (on Windows often IIS, a VPN client or another web server):

  • ./securax tls on checks first, changes nothing, and tells you how to find the program (netstat -ano | findstr :80 in PowerShell; the last number is its PID, Task Manager > Details shows the name).
  • If the ports become busy later, ./securax up and ./securax go switch back to http://localhost:8088 by themselves, so you are never left with nothing running. Free the port, then ./securax tls on && ./securax go again.

Limits

  • A risk-to-control link is a pointer to the control family that treats the risk, made from the risk's wording. Review it, and treat it as a starting point, not as an assessment.
  • The NSCS and national CII mappings are this project's reading of those documents. Check them against the originals before an audit.